Can I use multiple adapters with TamoGraph to make the scanning process faster?
Yes, TamoGraph can capture data from multiple channels simultaneously if you use multiple compatible USB adapters. This shortens the time needed to collect data from the channels being scanned as you move along the survey path, and, therefore, improves the data quality. For example, with the default 250 ms per channel interval, it takes five seconds to sweep through 20 channels if you use only one adapter. If you use three adapters, the same amount of data will be collected in less than two seconds. The following USB adapters can be used for multi-channel capturing: D-Link DWA-160 v.A1 and v.A2, NETGEAR WN111 v2, NETGEAR WNDA3100 v1, Proxim ORiNOCO 8494, SMC Networks SMCWUSB-N2, TP-Link TL-WN821N v1 and v2, TP-Link TL-WN822N, Ubiquiti SR71-USB, and CACE Technologies AirPcap Ex or NX. Note that different types of adapters cannot be mixed; all of the adapters should be of the same model. You should also install the same driver for all of the adapters.